contact  tell a friend  search  faqs  distributor area  imprint 
 
company
products
HumiCare® 200
humidifier H200
humidification chamber C200M
humidification chamber C200S
reusable tubings 16 mm
reusable tubings 9 mm
disposable tubing systems
accessories
HumiCare® 180
HumiCare FH-series
Auxiliary heaters
download product info
distribution
information
inquiry
 
Gründler GmbH
Carl-Benz-Straße 5
72250 Freudenstadt
GERMANY

phone: +49 (0)7441-9146-0
fax: +49 (0)7441-9146-77

reusable tubings 9 mm

For the smallest patients with their special needs there are special tubing systems and additional accessories available now.

These tubings are significantly smaller and lighter than our standard tubings with minimized compressible volume. This is advantageous e.g. when using high frequency oscillations and small tidal volumes for optimizing efficiency. As well the tractive forces at the patient connection are further reduced.

The established concept of integrated temperature probes has been maintained for reducing handling and potential error sources. Inspiratory and expiratory tubing are regulated and controlled separately concerning gas temperature.

Reprocessing is simply possible in washing machines for respiratory equipment or steam autoclaves (up to 134 °C ) without dismounting of any components.

 

A well known problem in conventional humidification technologies is the usage in combination with incubators or warming beds.

The different climate zones outside and inside the incubator/warming bed often lead to condensate formation within the tubings.

The new HumiCare® 200 tubing systems for incubators allow for an optimal condensate prevention highly independent of incubator and ambient climate as well as independent of respirator setting. This is valid for inspiratory and expiratory tubings so there should be no more need for water traps.

Also in neonatal therapy most ventilators and respiratory assist machinery is simply to combine with the HumiCare® 200.

For applications with a higher pressure inside the humidification chamber (e.g. some types of nCPAP systems) special solutions are available for optimizing the automatic water refill process. This sometimes seems to be a problem in the field with conventional humidification solutions.

By using the new products mentioned above the HumiCare® 200 is even easier and better to use for all kinds of artificial respiration and respiratory therapy. We are looking forward to assisting you in evaluating HumiCare® 200.

language
  
HumiCare® 200
© Gründler medical 2010